Water and electricity do not mix, so bathroom lighting follows rules that other rooms do not. The bulb is rarely the issue: the fitting is what provides protection. Still, knowing the zones helps you choose the right replacement and understand what is already installed.
The bathroom zones
| Zone | Where | Typical minimum protection for fittings |
|---|---|---|
| Zone 0 | inside the bath or shower tray | IPX7, extra low voltage only |
| Zone 1 | above the bath or shower, up to 2.25 m | IP65 is commonly used |
| Zone 2 | 60 cm around zone 1, and around the basin | IP44 at least |
| Outside zones | the rest of the room | no special rating, but IP20 or higher is wise if steamy |
These are the general principles used in UK wiring practice. Installing or changing a bathroom fitting is notifiable or specialist work in many cases, so leave it to a qualified electrician.
What the IP code means
The first digit is protection against solid objects and dust, the second against water. IP44 resists splashes from any direction; IP65 is dust tight and resists jets of water. A bulb on its own does not give a fitting an IP rating: keep the fitting’s seals, glass and gaskets in place when you change the lamp.
Light for the room
At the mirror
Neutral white (3500K to 4000K) with a high CRI shows true skin tones for shaving and make up.
General light
Wide beam GU10 spotlights (100° or more) spread light evenly in a small room.
Night use
A low, warm light avoids glare at night; a dimmable bulb or a separate low light helps.