How Many Lumens Do You Need for Each Room?

Lumens measure the total light a bulb gives. To decide how many you need, think about the room’s size and what you do in it. Lighting designers work in lux (lumens per square metre on a surface); the figures below are common planning values for homes.

Room General target Approximate lumens per m² of floor
Living room soft, layered light 100 to 200
Bedroom soft, plus reading light 100 to 150
Kitchen (worktops) bright task light 300 or more
Bathroom bright at the mirror 200 to 300
Hallway and stairs safe, even 100 to 150
Home office bright, glare free 300 to 500 on the desk
Garage and workshop bright for tasks 300 to 500

A simple method

  1. Measure the floor area: length × width in metres.
  2. Multiply by the figure for the room. A 4 × 3 m kitchen is 12 m²; at 300 lm per m² that is about 3600 lumens.
  3. Divide by the lumens per bulb. With spotlights of about 400 lm each, that means around 9 spotlights.

Not every lumen reaches the surface: dark walls and shades absorb some, so err on the generous side, and use dimmable bulbs if you want to turn it down in the evening.

Only know the old wattage? Use the watts to lumens converter. Want the exact lux under a spotlight? Try the lumen, lux and candela calculator.
Posted on

Why LED Bulbs Flicker and How to Fix It

A flickering LED is annoying and often tells you something about the circuit. Most causes are simple. Work through them in order.

1. A dimmer that does not suit LEDs

The most common cause. Either the bulb is not dimmable, or the dimmer is an old type made for filament loads, or the total LED wattage is below the dimmer’s minimum load. See dimmable LEDs and dimmers.

2. A 12V transformer made for halogens

MR16 and G4 bulbs run on 12V. Transformers designed for halogen loads may not run low power LEDs steadily. An LED driver or an LED rated transformer is the usual fix. See GU10 or MR16.

3. A glowing or flickering light when switched off

A faint glow or occasional blink with the switch off often comes from an illuminated switch, a smart switch or long cable runs that let a tiny current through. Fitting a different switch, or a component that an electrician can add, normally ends it.

4. A loose bulb or holder

With the power off, check that the bulb is seated firmly. A worn bayonet holder with weak springs can cause intermittent contact.

5. Mixed bulbs on one circuit

Different LED models on the same dimmer can react differently. Use the same model throughout.

6. The bulb itself

Swap the bulb with one from a light that works. If the flicker follows the bulb, the bulb is at fault. If it stays with the fitting, the cause is in the circuit.

If you notice a burning smell, buzzing from the fitting, scorch marks or a hot switch, switch off at the consumer unit and call a qualified electrician.
Posted on

What CRI Means on a LED Bulb

The colour rendering index (CRI, sometimes written Ra) measures how faithfully a light source shows the colours of objects, compared with a reference light such as daylight or a filament bulb. It runs up to 100.

CRI What to expect
Below 80 colours can look flat or slightly off, especially reds and skin tones
80 to 89 good for most rooms; the usual level for household LEDs
90 and above very natural colours; best for kitchens, bathrooms, make up and art

CRI is not colour temperature

Kelvin tells you whether the light is warm or cool. CRI tells you whether colours look right under it. A 2700K bulb can have CRI 80 or CRI 95. See warm white or cool white.

Where it matters most

Kitchen

Food looks more natural; it is easier to judge freshness and cooking.

Bathroom mirror

True skin tones for shaving and make up.

Wardrobe and hobbies

Matching clothes, painting, sewing.

When a product page here states a CRI, it is the figure given in the listing we work from. When none is stated, we do not guess.

Posted on

Filament LED or Standard LED Bulbs: Which Gives the Better Light?

LED bulbs come in two very different styles. Filament LEDs copy the look of a clear Edison bulb, with thin glowing strands inside clear or amber glass. Standard LEDs hide their chips under a frosted dome. Both use LED chips; the difference is how the light leaves the bulb.

Filament LED Standard LED
Look clear or tinted glass, visible strands frosted, uniform glow
Best in bare pendants, open shades, decorative fittings closed shades, ceiling lights, lamps
Glare can dazzle in a bare fitting at high output soft, diffused
Light spread all around, like a classic bulb mostly upwards and sideways for many models
Colour often very warm, especially with amber glass wide choice from 2700K to 6500K

When to choose filament

A bulb that is on show, in a cage pendant, a glass lantern or a row over a bar, is where filament LEDs shine. Amber glass versions give a cosy, candle like glow, at the cost of some brightness.

When to choose standard

For light to read by, in a closed shade or a ceiling fitting, a standard frosted LED gives more usable light with less glare.

Amber and smoked glass filament bulbs give noticeably fewer lumens than clear ones. Check the lumen figure if the bulb is your only light in the room.
Posted on

B22 or E27? Bayonet and Screw Caps Explained

The United Kingdom is one of the few countries where the bayonet cap is still the standard for household bulbs. Most of Europe uses the Edison screw. Both are common in British homes, often side by side, because imported lamps and pendants tend to use screw caps.

B22

Bayonet (B22, BC)

A smooth metal sleeve with two small lugs on opposite sides. Push in and turn a little to lock.

E27

Edison screw (E27, ES)

A threaded metal sleeve. Screw in clockwise until it is snug.

The small versions

Name Also called Diameter Typical use
B22 BC, bayonet cap 22 mm pendants and lamps in UK homes
B15 SBC, small bayonet 15 mm small lamps, appliances, fridges
E27 ES, Edison screw 27 mm European style lamps
E14 SES, small Edison screw 14 mm chandeliers, candle bulbs, cooker hoods

Can I use an adapter?

Cap adapters exist, but they make the bulb longer, which can leave it sticking out of a shade, and they add a joint that can loosen. Buying a bulb with the correct cap is the simpler and safer solution.

The shape names

Caps tell you what fits; shape codes tell you how it looks. A60 is the classic pear shape, G95 and G125 are large globes, P45 is a golf ball, C35 a candle and ST64 a vintage teardrop. The number is the diameter in millimetres.

Posted on

Beam Angles Explained for LED Spotlights

The beam angle is the width of the cone of light a spotlight produces, measured where the brightness falls to half of its peak. It changes the look of a room as much as the brightness does.

How wide the pool of light is

The diameter of the lit circle is about 2 × height × tan(angle ÷ 2). From a ceiling 2.4 m above the floor:

Beam angle Approximate circle on the floor Character
24° about 1.0 m very focused accent light
36° about 1.6 m classic halogen look, defined pools
60° about 2.8 m even general lighting
120° about 8.3 m (in practice it lights walls too) wide flood, soft light

Choosing

Narrow (under 40°)

Pictures, shelves, a worktop or a dramatic look with contrast.

Medium (around 60°)

Kitchens, hallways and living rooms with several downlights.

Wide (100° and more)

Bathrooms, small rooms, low ceilings and fewer fittings.

Spacing downlights

A common rule of thumb for even light is to space downlights roughly as far apart as the ceiling is high, and about half that distance from the walls. Narrow beams need closer spacing, wide beams allow more space between fittings.

Brightness and beam go together

For the same lumens, a narrow beam concentrates light and looks brighter where it lands; a wide beam spreads it. The candela figure, when stated, measures this intensity in the centre. Try it in the lumen, lux and candela calculator.

Posted on

How to Choose LED Bulbs for the Bathroom: IP Ratings and Zones

Water and electricity do not mix, so bathroom lighting follows rules that other rooms do not. The bulb is rarely the issue: the fitting is what provides protection. Still, knowing the zones helps you choose the right replacement and understand what is already installed.

The bathroom zones

Zone Where Typical minimum protection for fittings
Zone 0 inside the bath or shower tray IPX7, extra low voltage only
Zone 1 above the bath or shower, up to 2.25 m IP65 is commonly used
Zone 2 60 cm around zone 1, and around the basin IP44 at least
Outside zones the rest of the room no special rating, but IP20 or higher is wise if steamy

These are the general principles used in UK wiring practice. Installing or changing a bathroom fitting is notifiable or specialist work in many cases, so leave it to a qualified electrician.

What the IP code means

The first digit is protection against solid objects and dust, the second against water. IP44 resists splashes from any direction; IP65 is dust tight and resists jets of water. A bulb on its own does not give a fitting an IP rating: keep the fitting’s seals, glass and gaskets in place when you change the lamp.

Light for the room

At the mirror

Neutral white (3500K to 4000K) with a high CRI shows true skin tones for shaving and make up.

General light

Wide beam GU10 spotlights (100° or more) spread light evenly in a small room.

Night use

A low, warm light avoids glare at night; a dimmable bulb or a separate low light helps.

Never fit a bulb with wet hands, and switch off at the wall first. If a bathroom fitting shows condensation inside, rust or a cracked cover, stop using it and call an electrician.
Posted on

How to Choose LED Bulbs for the Kitchen

The kitchen is the room where lighting works hardest. You chop, read recipes, check food and clean, often in the evening. Three layers of light do the job best.

General light

Ceiling spotlights or a fitting that lights the whole room evenly.

Task light

Light on the worktops, often from under the wall cabinets, so you do not work in your own shadow.

Accent light

Pendants over a table or island for a warmer, softer mood.

Brightness

Kitchens need more light than living rooms. A common rule of thumb for planning is around 300 lux on worktops; use our lux calculator to check a layout, and how many lumens per room for a quick estimate.

Colour temperature

3000K suits kitchen diners and keeps a homely feel. 4000K gives a crisper light for cooking areas. Keep one temperature across the ceiling.

Beam angle for spotlights

Narrow beams (around 36°) create pools of light and dark gaps between fittings. For an even ceiling, 60° or wider is usually better.

Colour rendering

Food looks more appetising, and it is easier to see whether meat is cooked, under a bulb with a high CRI. Look for CRI 80 or above, ideally 90. See what CRI means.

Near the hob

Cooker hood lights often use small caps such as E14, G4 or narrow tubes, and run warm. Choose a replacement that the product page says suits a cooker hood, and match the cap and size exactly.

Posted on

Dimmable LED Bulbs and Dimmer Switches: What Works Together

Dimming worked with any filament bulb because the dimmer simply reduced the power. LEDs contain electronics that turn mains electricity into the low voltage the chip needs, and those electronics only dim properly when they are designed to.

Two conditions

The bulb must be dimmable

It says so on the box and the product page. A non dimmable LED on a dimmer may flicker, buzz or fail early.

The dimmer must suit LEDs

Older dimmers were made for high wattage filament loads. LED compatible dimmers handle the low wattage of LEDs.

Minimum load

Many older dimmers need a minimum load, often 40W or more. Six 5W LEDs add up to only 30W, which can be below it. Symptoms are flicker at low settings or lights that will not turn fully off. An LED dimmer with a low minimum load, fitted by an electrician, usually solves it.

Leading edge and trailing edge

Dimmers cut part of the mains wave. Leading edge dimmers are the older type; trailing edge dimmers are generally better suited to LEDs. The dimmer’s packaging or the faceplate’s data usually says which it is.

Tips

  • Use the same model of bulb on one dimmer for an even result.
  • If a dimmed light flickers only at the bottom of the range, adjust the dimmer’s minimum setting if it has one.
  • Smart bulbs are dimmed by their app, and should be on a normal switch, not a dimmer.
Replacing a dimmer switch means working on the mains wiring. Switch off at the consumer unit and use a qualified electrician if you are not competent to do it.
Posted on

How to Read the UK Energy Label on Light Bulbs

Light bulbs sold in Great Britain carry an energy label on the packaging, and online sellers are expected to show the energy class next to the price. Since the 2021 rescale, the label uses a stricter A to G scale, so many LEDs that were once “A++” now appear as E or F. That does not mean they became worse: the scale was reset to leave room for better products.

What is on the label

Energy class

A coloured arrow from A (most efficient, dark green) to G (least efficient, red).

kWh/1000h

The energy the bulb uses in 1000 hours of operation. A 6W bulb uses 6 kWh in 1000 hours.

QR code

Links to the product’s entry in the official product database, with its full data.

Using the label

  1. Compare bulbs with the same cap, brightness and colour temperature.
  2. For those, a better class or a lower kWh/1000h figure means less energy for the same use.
  3. Look for the product information sheet, which lists lumens, colour temperature, CRI and lifetime data declared by the manufacturer.

Calculating your own cost

Multiply the kWh/1000h figure by the hours you expect to use the bulb, divide by 1000, and multiply by the unit rate on your electricity bill. Our LED savings calculator does the sum for you.

Where a product page here does not show a label, it means the listing we work from did not provide one. Ask us before ordering if you need the class for a specific bulb.
Posted on

GU10 or MR16? How to Tell Your Spotlight Bulbs Apart

Spotlight bulbs come in two very common types that look almost identical from the front: GU10 and MR16. Buying the wrong one is the most frequent mistake when replacing downlights.

GU10

GU10: mains voltage

Two short, thick pins with a wider tip. Push in and twist a quarter turn. Runs directly on 230V.

MR16

MR16 (GU5.3): 12 volt

Two thin, straight wire pins. Pushes straight in, usually held by a spring clip. Needs a 12V transformer.

Other clues

  • Removing the bulb: a GU10 twists out; an MR16 pulls out, often after removing a retaining clip.
  • Printed marking: look for “GU10” or “230V” against “MR16”, “GU5.3” or “12V”.
  • Above the ceiling: MR16 fittings have a small transformer box near each light or one for several lights.

Switching MR16 halogens to LED

An MR16 LED fits the same holder, but the transformer matters. Many transformers made for halogen loads need a minimum load to work properly, and a few low power LEDs fall below it, causing flicker or lights that do not come on. If that happens, the usual remedy is an LED driver or a transformer rated for LED loads, fitted by an electrician. Some households choose to convert the fittings to GU10 instead, which removes the transformer altogether; that is a wiring change for an electrician.

Same size, same look

Both are usually 50 mm across, so they fit the same downlight openings. Some LED versions are a few millimetres longer than the halogen they replace, so check the depth if your fitting is shallow.

More help: replacing halogen spotlights and beam angles explained.

Posted on

Lumens per Watt Explained: What Luminous Efficacy Means

Watts measure the power a bulb takes from the mains. Lumens measure the light it gives out. Divide one by the other and you get luminous efficacy, in lumens per watt (lm/W): the most direct measure of how efficient a light source is.

Formula: efficacy (lm/W) = luminous flux (lm) ÷ power (W). A bulb giving 806 lm for 8W has an efficacy of about 100 lm/W.

Why watts stopped meaning brightness

With filament bulbs, everybody knew that 60W was a normal room bulb and 100W was bright. That worked because all filament bulbs had roughly the same efficacy. LEDs vary: two 8W LEDs can give quite different amounts of light. Lumens are the figure to compare.

The eye is part of the definition

The lumen is weighted by the sensitivity of the human eye, which is greatest for yellow green light. That is why a lumen is a measure of useful, visible light rather than raw radiant power. The theoretical maximum, for a pure yellow green light at 555 nm, is 683 lm/W; white light necessarily sits well below that.

Related units

Quantity Unit Meaning
Luminous flux lumen (lm) total visible light leaving the bulb
Luminous intensity candela (cd) light in a given direction, important for spotlights
Illuminance lux (lx) light falling on a surface, 1 lx = 1 lm per m²

Try them with the lumen, lux and candela calculator, or convert an old wattage with the watts to lumens converter.

Comparing two bulbs

  1. Check that both have the same cap and colour temperature.
  2. Compare the lumens: that is the brightness.
  3. Compare the watts: fewer watts for the same lumens means a more efficient bulb.
  4. Check the CRI if colour matters, for example in a kitchen or at a make up mirror.