Posted on

LED vs Fluorescent Bulbs: Advantages and Disadvantages

Before LEDs became affordable, fluorescent lamps were the energy saving choice: long tubes in kitchens and garages, compact folded bulbs in living rooms. Both technologies beat filament bulbs. Here is how they compare with each other.

Point Fluorescent (tube or CFL) LED
Full brightness after a warm up, slower in the cold instantly
Mercury contains a small amount none
Frequent switching shortens its life no effect worth noting
Dimming only special versions bulbs sold as dimmable, with a compatible dimmer
Direction of light all around can be all around or focused
Availability in Great Britain most types phased out (2023) widely available

Where fluorescent still had an edge

Fluorescent tubes spread soft light evenly along their length, and in old fittings they were cheap to replace. Modern LED tubes and battens now give the same even light. A few cheap LEDs flicker or render colours poorly; choosing a bulb with a stated CRI of 80 or more avoids most of that.

Advantages of LED

  • lower power for the same light
  • no warm up and no mercury
  • a wide choice of shapes, caps and colour temperatures
  • focused versions for spotlights

Disadvantages of LED

  • dimming needs a compatible dimmer
  • quality varies between products, so compare stated lumens and CRI
  • the electronics in the base dislike enclosed hot fittings unless the bulb is rated for them

Ready to switch? Read replacing compact fluorescent bulbs or replacing fluorescent tubes.

Posted on

LED, Halogen and Incandescent Bulbs Compared

Three technologies have lit British homes over the last century. They all turn electricity into light, but in very different ways, and the difference shows on the bill.

How each one works

Incandescent

A thin tungsten filament is heated until it glows. Most of the energy leaves as heat, not light.

Halogen

A filament inside a small capsule filled with halogen gas, which lets it run hotter and a little more efficiently. Still mostly heat.

LED

A semiconductor chip emits light directly when current passes through it. Far less energy is lost as heat.

Light for the same brightness

The useful measure is luminous efficacy: lumens of light per watt of electricity. The figures below are typical orders of magnitude; the exact value of any bulb is on its packaging or product page.

Incandescent Halogen LED
Typical efficacy around 10 to 15 lm/W around 15 to 20 lm/W commonly 80 lm/W and above
Power for about 800 lm about 60W about 42 to 46W usually 7 to 10W
Heat at the bulb very hot very hot warm, mainly at the base
On sale in Great Britain household types phased out most types phased out from 2021 yes

What it means in practice

  • Power: an LED giving the same light as a 60W filament bulb typically draws well under a fifth of the power.
  • Heat: halogen spotlights in a ceiling can heat the void above them; LEDs run much cooler.
  • Light quality: filament and halogen bulbs render colours perfectly (CRI 100). Good LEDs reach CRI 80 to 90 and above; see what CRI means.
  • Dimming: filament bulbs dim on any dimmer. LEDs need to be sold as dimmable and an LED compatible dimmer.

Work out the difference for your own bulbs with the LED savings calculator, or read lumens per watt explained for the physics.

Posted on

Simple Ways to Cut Lighting Costs at Home

Lighting is one of the easiest parts of a household electricity bill to reduce, because the changes are cheap and need no building work. Here are the steps that make the biggest difference, in order.

1. Replace the bulbs that are on the longest

Start with the kitchen, living room and hallway, the lights that stay on for hours every evening. An LED uses a fraction of the power of a filament or halogen bulb giving similar light. A bulb used four hours a day saves far more than one in a cupboard used a minute a day. Our LED savings calculator estimates the difference for your own bulbs and electricity rate.

2. Match the brightness to the job

Overlit rooms waste energy. Use the lumen figure to choose: general light in a living room needs less than a kitchen worktop. See how many lumens you need for each room.

3. Light the task, not the whole room

A desk lamp or under cabinet light where you work lets you keep the ceiling lights lower or off.

4. Use controls

Dimmers

Dimming an LED reduces its power use. Use dimmable bulbs on an LED compatible dimmer.

Motion sensors

Ideal for hallways, garages and outdoor lights that are often left on.

Timers and smart bulbs

Schedules switch lights off when nobody is home.

5. Make the most of daylight

Pale walls and ceilings reflect more light, so fewer bulbs are needed. Keep windows and light shades clean; dust can absorb a surprising share of the light.

6. Switch off

An LED does not wear out faster when it is switched on and off, so turning it off when you leave a room always saves energy.

Solar panels were often suggested alongside efficient lighting. They are a separate project that needs a professional survey; for lighting itself, LED bulbs and good habits bring the quickest results.
Posted on

Warm White or Cool White? Choosing a Colour Temperature Room by Room

Two LED bulbs with the same brightness can make a room feel completely different. The difference is the colour temperature, given in kelvin (K) on every LED box and product page.

2700K3000K4000K5000K6500K
Kelvin Name on the box What it looks like
2700K warm white, extra warm the yellowish glow of an old filament bulb
3000K warm white, soft white warm but a little cleaner, close to halogen
4000K neutral white, cool white bright, natural white with no yellow
5000K to 6500K daylight crisp, slightly bluish white

Room by room

Living room and bedroom

2700K to 3000K. Warm light feels relaxing in the evening. Dimmable bulbs help here.

Kitchen

3000K for a warm kitchen diner, 4000K over worktops where you want to see clearly.

Bathroom

3000K to 4000K. Neutral light shows true skin tones at the mirror.

Home office

4000K keeps reading and screen work comfortable during the day.

Garage, workshop, utility

4000K to 6500K for detailed tasks and good contrast.

Hallway and stairs

3000K matches neighbouring rooms and avoids a harsh contrast at night.

Keep one temperature per room

Mixing 2700K and 6500K bulbs in the same room looks uneven: one corner appears yellow, the other blue. When you replace a few spotlights, buy the same kelvin for the whole ceiling. If you are replacing old halogens, 3000K is the closest match to their light.

Colour temperature is not the same as colour quality. A bulb can be 4000K and still render colours poorly. That is measured by the CRI, explained in what CRI means.
Posted on

Replacing Fluorescent Tubes with LED Tubes in Your Garage or Workshop

Long fluorescent tubes light garages, workshops, kitchens and offices across the country. In Great Britain, the common T8 tubes in 2, 4 and 5 foot lengths were phased out of sale from 1 September 2023 under the ecodesign rules for lighting. When a tube fails, the replacement is now an LED tube or a new LED batten.

Know your tube

Type Diameter Common lengths
T8 26 mm (1 inch) 600 mm (2 ft), 1200 mm (4 ft), 1500 mm (5 ft)
T5 16 mm (5/8 inch) 549 mm, 849 mm, 1149 mm, 1449 mm

Measure the tube including its end caps and check the printed code. A T8 LED tube will not fit a T5 holder, and lengths are not interchangeable.

The two kinds of LED tube

Ballast compatible (plug and play)

Designed to work with the existing fitting. Usually you replace the old starter with the supplied LED starter, then fit the tube. Only use the combinations the tube’s instructions list.

Mains direct (ballast bypass)

The fitting is rewired so mains power goes straight to the tube ends and the ballast is removed. This is permanent electrical work.

Safety first. Rewiring a fitting to bypass the ballast is electrical work and should be done by a qualified electrician, who will also label the fitting so nobody later puts a fluorescent tube back in. If the product page does not say clearly which type a tube is, ask before you buy.

When a new batten makes more sense

Old fittings with corroded holders, cracked diffusers or noisy ballasts are often better replaced by an integrated LED batten, which has the light source built in. An electrician can swap a batten quickly, and you avoid relying on the old components.

Old tubes are hazardous waste

Fluorescent tubes contain mercury. Keep them whole, and take them to a household waste recycling centre that accepts lamps. See recycling your old bulbs.

Posted on

Replacing Compact Fluorescent Bulbs with LED

Compact fluorescent lamps, the folded or spiral “energy saving bulbs” sold from the 1990s, were the first mass market alternative to filament bulbs. In Great Britain, compact fluorescent lamps without an integrated ballast were phased out of sale from 24 February 2023, and the rules for the others tightened at the same time. LED bulbs now do the same job with no warm up time and no mercury.

Why switch now

Instant full light

CFLs take time to reach full brightness, especially when cold. LEDs are bright as soon as they are switched on.

No mercury

CFLs contain a small amount of mercury and must be recycled. LEDs contain none.

Same caps

Most CFLs used B22, E27, E14 or B15 caps, and LED bulbs exist in all of them.

How to choose the replacement

  1. Cap: read it on the old bulb (B22 bayonet is the most common in UK homes).
  2. Brightness: CFL boxes often said “equivalent to 60W”. Look for an LED with a similar lumen figure; a typical 60W filament bulb gave about 800 lumens.
  3. Colour: most household CFLs were warm white, around 2700K. Choose 2700K or 3000K for the same feel.
  4. Shape: a standard A60 shape LED is shorter than many spiral CFLs and usually fits shades that held them.

Disposing of the old CFL

Do not put compact fluorescent bulbs in household waste. Take them to a household waste recycling centre or a shop that collects lamps. If one breaks, open a window, leave the room for a few minutes, then sweep up the pieces with card (not a vacuum cleaner) and place them in a sealed bag for the recycling centre. Our page on recycling your old bulbs has the details.

Looking for the old comparison of LED and fluorescent technology? Read LED vs fluorescent bulbs.
Posted on

Replacing Halogen Spotlights with LEDs after the UK Phase Out

Halogen spotlights were for years the standard bulb in UK kitchens, bathrooms and hallways. Under the ecodesign rules for lighting, most mains halogen lamps were phased out of sale in Great Britain from 1 September 2021, and the remaining halogen capsules and low voltage types followed in later stages. Shops may sell remaining stock, but new supplies of the common types are gone. The good news is that LED spotlights fit the same holders.

Step 1: check the cap and the voltage

A GU10 halogen (two stubby pins, twist to lock) runs on mains 230V and is replaced by a GU10 LED directly. An MR16 halogen (two thin pins) runs on 12V through a transformer hidden above the ceiling. An MR16 LED needs a transformer that works with LED loads; the older transformers built for halogen loads sometimes make LEDs flicker or stay off. See our guide on telling GU10 and MR16 apart.

Step 2: match the brightness in lumens, not watts

Halogen spotlights were sold by watts, typically 35W or 50W. LED spotlights draw far less power, so compare the light output in lumens printed on the box or the product page. A higher lumen figure means a brighter bulb. When the seller does not state lumens, compare with another bulb whose lumens you know, or start with a bulb in the same wattage range as one you have already tried.

Step 3: choose the beam angle

Beam angle Effect Where it suits
24° to 38° narrow, focused pool of light highlighting a worktop, a picture, a shelf
60° medium spread general downlighting in kitchens and hallways
100° to 120° wide, soft flood bathrooms, small rooms, fewer fittings

Halogens were often around 36°. If your room felt patchy with halogens, a wider LED beam will even it out. More detail in beam angles explained.

Step 4: pick the colour

Halogen light is warm, close to 2700K to 3000K. Choose warm white (2700K to 3000K) to keep the same feel, or neutral white (4000K) for a crisper kitchen or utility room. Read warm white or cool white for a room by room guide.

Step 5: dimmers

A halogen on a dimmer needs a bulb sold as dimmable, and a dimmer switch that works with LED loads. Fitting a non dimmable LED on a dimmer can cause buzzing, flicker or early failure. Our dimmer guide explains what to check.

Bathroom spotlights sit in zones where water may reach them. Keep the fitting’s own protection (for example a sealed IP65 downlight) and never remove a cover or seal to fit a bulb. Replacing a bulb is a simple job; changing the fitting or its wiring is work for a qualified electrician.
Posted on

How to Identify Your Light Bulb Fitting

The cap is the part of the bulb that goes into the light fitting. Buying the right wattage or colour means nothing if the cap is wrong, so this is always the first thing to check. Switch the light off, let the bulb cool for a few minutes, take it out and look at its base.

The three families of caps

Pin caps

Two metal pins. GU10 pins have thick ends and twist into place; MR16 (GU5.3) and G4 pins are thin and push straight in; G9 is a loop of wire that pushes in.

Screw caps

A threaded metal sleeve. E27 is the standard Edison screw (27 mm), E14 the small Edison screw (14 mm).

Bayonet caps

A smooth sleeve with two small lugs on the sides. B22 is the classic British bayonet (22 mm), B15 the small bayonet (15 mm).

Quick identification table

Cap What you see Usual voltage Typical use
GU10 2 short pins with thick ends, push and twist 230V mains kitchen and bathroom downlights, track lights
MR16 / GU5.3 2 thin straight pins, 5.3 mm apart 12V (needs a transformer) older low voltage downlights, display lighting
B22 smooth sleeve, 2 side lugs, 22 mm 230V pendants and table lamps in most UK homes
B15 smooth sleeve, 2 side lugs, 15 mm 230V small lamps, cooker hoods, fridges
E27 screw thread, 27 mm 230V European style lamps and pendants
E14 screw thread, 14 mm 230V chandeliers, candle bulbs, small lamps
G9 a looped wire pin, pushes in 230V small decorative fittings, wall lights
G4 2 very thin straight pins, 4 mm apart 12V cabinet lights, cooker hoods, caravans
GU10 or MR16? Both are spotlight shaped and the same size. Look at the pins: GU10 pins are short and stubby with a wider tip, MR16 pins are thin straight wires. If you are not sure, read our guide GU10 or MR16.

Read the old bulb before you throw it away

Most bulbs have their details printed on the glass, the cap or the plastic body: cap type, wattage, voltage and often a code such as “PAR16” or “A60” for the shape. Write these down. The shape matters too: a candle bulb in a chandelier or a small globe in a glass shade may not fit if you choose a larger LED with the same cap.

Measure if nothing is printed

  • Measure the width of a screw or bayonet sleeve across: about 27 mm for E27, 22 mm for B22, 14 or 15 mm for E14 and B15.
  • For pin bulbs, measure the gap between the centres of the pins: 10 mm for GU10, 5.3 mm for MR16, 4 mm for G4, 9 mm for G9.
  • Measure the length and diameter of the glass if the fitting has a shade or a recess. LED bulbs are sometimes a little longer than the bulbs they replace.
Always switch off at the wall and let a halogen bulb cool before removing it: halogen spotlights run hot enough to burn fingers. If a fitting is damaged, scorched or the wiring is visible, do not fit a new bulb; ask a qualified electrician to look at it.

Once you know your cap, browse the matching section of the shop from the home page, or read how many lumens you need for each room.